Program 30 : DSS/DLS Console Setup
30-02 : DSS Console Extension Assignment
Level
IN
Description
Use Program 30-02 : DSS Console Extension Assignment to identify which extensions have DSS
Consoles connected.
• Up to 12 different extensions with DSS Consoles can be set up. A single extension can have up to
four 60-button DSS Consoles (12 is the maximum allowed per system).
When programming, each extension/DSS Console(s) combination is called a Console Number. There
are 12 Console Numbers (01 ~ 12). Console Numbers can be assigned to extensions. When entering
data, the assignment for Console Number 1 is normally made first.
Input Data
60-button DSS Console Number 01 ~ 12
Item No. Item Default
01 Extension Number
The extension number for the multiline terminal connected
with the DSS console (up to four digits) .
No setting
Conditions
None
Feature Cross Reference
• Direct Station Selection (DSS) Console
ISSUE 1.1 SL1000
Program
30
Programming Manual 2-297