Program 32 : Door Box and Sensor Setup
32-01 : Door Box Timers Setup
Level
IN
Description
Use Program 32-01 : Door Box Timers Setup to assign the timers used for the Door Box.
The Door Box feature is called Door Phone when programming via WebPro and using a multiline terminal.
Input Data
Item No. Item Input Data Default
01 Door Box Answer Time
A multiline terminal user must answer Door Box chimes
during this time.
0 ~ 64800 seconds 30 seconds
02 Door Lock Cancel Time
When a single line telephone user hook flashes or a mul-
tiline user presses the Recall key while talking to a Door
Box, the strike stays open for this time.
0 ~ 64800 seconds 10 seconds
03 Off-Premise Call Forward by Door Box Disconnect
Timer
Define the conversation period for an Off-Premise Call
Forward by Door Box call. When this timer expires, the
caller hears busy tone for three seconds (fixed time), and
the call is then disconnected.
0 ~ 64800 seconds 60 seconds
Conditions
None
Feature Cross Reference
Door Box
ISSUE 1.1SL1000