EasyManua.ls Logo

NEC SL100 - MFC Tone Receiver Setup; Table 2-16 Default Table

NEC SL100
598 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 80 : Basic Hardware Setup for System
80-11 : MFC Tone Receiver Setup
Level
IN
Description
Use Program 80-11 : MFC Tone Receiver Setup to various data for the MFC signal detection.
Input Data
MFC Tone Receiver Type Number 1 = MFC Receiver for Extension
2 = MFC Receiver for Trunk
3 = Reserved
4 = Reserved
5 = Reserved
Item No. Item Input Data
01 Detect Level 0=0dBm~-25dBm
1=-5dBm~-30dBm
2=-10dBm~-35dBm
3=-15dBm~-40dBm
4=-20dBm~-45dBm
5=-25dBm~-50dBm
6=-30dBm~-55dBm
02 Start delay time 0~255(0.25step,0ms~64ms)
03 Min. detect level 0~15
detectlevel0=-10dBm(0)~-25dBm(15)
detectlevel1=-15dBm(0)~-30dBm(15)
detectlevel2=-20dBm(0)~-35dBm(15)
detectlevel3=-25dBm(0)~-40dBm(15)
detectlevel4=-30dBm(0)~-45dBm(15)
detectlevel5=-35dBm(0)~-50dBm(15)
detectlevel6=-40dBm(0)~-55dBm(15)
04 Max. detect level 0~15
detectlevel0=0dBm(0)~-15dBm(15)
detectlevel1=-5dBm(0)~-20dBm(15)
detectlevel2=-10dBm(0)~-25dBm(15)
detectlevel3=-15dBm(0)~-30dBm(15)
detectlevel4=-20dBm(0)~-35dBm(15)
detectlevel5=-25dBm(0)~-40dBm(15)
detectlevel6=-30dBm(0)~-45dBm(15)
05 Twist level 0~9(1dB~10dB)
06 S/N ratio 0~4(-5step,0dB~-20dB)
07 ON detect time 1 ~ 255 (15 step, 30 ms ~ 3840 ms)
08 OFF detect time 1 ~ 255 (15 step, 30 ms ~ 3840 ms)
Table 2-16 Default Table
Item Name Type 1 Type 2 Type 3 Type 4 Type 5
01 Detect Level 00000
02 Start delay time 00000
03 Min. detect level 15 (- 25 dBm) 15 (- 25 dBm) 15 (- 25 dBm) 15 (- 25 dBm) 15 (- 25 dBm)
04 Max. detect level 0 (0 dBm) 0 (0 dBm) 0 (0 dBm) 0 (0 dBm) 0 (0 dBm)
05 Twist level 9 (10 dBm) 9 (10 dBm) 9 (10 dBm) 9 (10 dBm) 9 (10 dBm)
06 S/N ratio 2 (0 dBm) 2 (0 dBm) 2 (0 dBm) 2 (0 dBm) 2 (0 dBm)
ISSUE 1.1 SL1000
Program
80
Programming Manual 2-423

Table of Contents