EasyManua.ls Logo

NEC SL100 - Page 453

NEC SL100
598 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item No. Item Description Input Data Default
13 T314 Specifies the timer value in 1/100ths of a
second of the timer to be started when
message segment is received.
1 ~ 254 seconds 4 seconds
14 T316 Specifies the timer value in 1/100ths of a
second of the timer to be started when RE-
START is sent.
(T317 + 1) ~ 254 sec-
onds
120 seconds
15 T317 Specifies the timer value in 1/100ths of a
second of the timer to be started when RE-
START is received.
1 ~ (T316-1) 60 seconds
16 T318 Specifies the timer value in 1/100ths of a
second of the timer to be started when
RES is sent. This timer is valid for user
side use only.
1 ~ 254 seconds 4 seconds
17 T319 Specifies the timer value in 1/100ths of a
second of the timer to be started when
SUSPEND is sent. This timer is valid for
user side use only.
1 ~ 254 seconds 4 seconds
18 T320 Specifies the timer value in 1/100ths of a
second when B-channel access: connec-
tion is received or D-channel access: DL-
ESTABLISH confirmation or indication is
received.
1 ~ 254 seconds 30 seconds
19 T321 Specifies the timer value in 1/100ths of a
second of the timer to be started when
STATUS ENQ is received.
1 ~ 254 seconds 30 seconds
20 T322 Specifies the timer value in 1/100ths of a
second upon D-channel failure.
1 ~ 254 seconds 4 seconds
Conditions
None
Feature Cross Reference
ISDN Compatibility
ISSUE 1.1 SL1000
Program
81
Programming Manual 2-431

Table of Contents

Related product manuals