Program
Number
Program Name Default Note
80-04-01 Call Progress Tone Detector Setup - Detection
Level
Type 1 (DT) = 0 (-25dBm)
Type 2 (BT) = 0 (-25dBm)
Type 3 (RBT) = 0 (-25dBm)
Type 4 = 0
Type 5 = 0
80-04-02 Call Progress Tone Detector Setup - Min. Detec-
tion Level
Type 1 (DT) = 15 (-25dBm)
Type 2 (BT) = 15 (-25dBm)
Type 3 (RBT) = 15 (-25dBm)
Type 4 = 0
Type 5 = 0
80-04-03 Call Progress Tone Detector Setup - S/N Ratio Type 1 (DT) = 4 (-20dB)
Type 2 (BT) = 4 (-20dB)
Type 3 (RBT) = 4 (-20dB)
Type 4 = 0
Type 5 = 0
80-04-04 Call Progress Tone Detector Setup - No tone time Type 1 (DT) = 132 (3990ms)
Type 2 (BT) = 132 (3990ms)
Type 3 (RBT) = 132 (3990ms)
Type 4 = 0
Type 5 = 0
80-04-05 Call Progress Tone Detector Setup - Pulse Count Type 1 (DT) = 1
Type 2 (BT) = 1
Type 3 (RBT) = 1
Type 4 = 0
Type 5 = 0
80-04-06 Call Progress Tone Detector Setup - ON minimum
time
Type 1 (DT) = 63 (1920ms)
Type 2 (BT) = 12 (390ms)
Type 3 (RBT) = 25 (780ms)
Type 4 = 0
Type 5 = 0
80-04-07 Call Progress Tone Detector Setup - ON maximum
time
Type 1 (DT) = 0
Type 2 (BT) = 20 (630ms)
Type 3 (RBT) = 40 1230ms)
Type 4 = 0
Type 5 = 0
80-04-08 Call Progress Tone Detector Setup - OFF mini-
mum time
Type 1 (DT) = 1 (60ms)
Type 2 (BT) = 12 (390ms)
Type 3 (RBT) = 52 (1590ms)
Type 4 = 0
Type 5 = 0
80-04-09 Call Progress Tone Detector Setup - OFF maxi-
mum time
Type 1 (DT) = 1 (60ms)
Type 2 (BT) = 20 (630ms)
Type 3 (RBT) = 80 (2430ms)
Type 4 = 0
Type 5 = 0
Operation
To store a Speed Dialing number (display telephones only):
1. Press Speaker key.
2. Dial 853 (for system) or 854 (for group).
3. Dial system or group storage code.
Initially, there are 900 System Speed Dialing codes. Group Speed Dialing codes must be defined in
programming.
ISSUE 2.0 SL1000/SL1100
Features and Specifications Manual 1-7
A