Program
Number
Program Name Default
25-07-07 System Timers for VRS/DISA - Ling Conversation
Warning Tone Time
30 (seconds)
25-07-08 System Timers for VRS/DISA - Long Conversation Dis-
connect Time
15 (seconds)
Method B - Tandem Trunking with Transfer Key
Program
Number
Program Name Default
14-01-04 Basic Trunk Data Setup - Transmit Gain Level for Con-
ference and Transfer Calls
32 (0dB)
14-01-05 Basic Trunk Data Setup - Receive Gain Level for Con-
ference and Transfer Calls
16 (-8dB)
14-01-13 Basic Trunk Data Setup - Trunk-to-Trunk Transfer 0
14-02-12 Analog Trunk Data Setup - Detect Network Disconnect
Signal
0
15-07-01 Programmable Function Keys Refer to Programming Manual.
20-06-01 Class of Service for Extensions All extension port = Class 1
20-07-11 Class of Service Options (Administrator Level) - Forced
Trunk Disconnect (analog trunk only)
COS 01~15 = 1
20-11-14 Class of Service Options (Hold/Transfer Service) -
Trunk-to-Trunk Transfer Restriction
COS 01~15 = 0
20-11-21 Class of Service Options (Hold/Transfer Service) - Re-
striction for Tandem Trunking on Hang Up
COS 01~15 = 0
20-13-10 Class of Service Options (Supplementary Service) -
Barge-In Monitor
COS 01~15 = 0
24-02-07 System Options for Transfer - Trunk-to-Trunk Transfer
Release Warning Tone
1800 (seconds)
24-02-10 System Options for Transfer - Disconnect Trunk-to-
Trunk
0 (seconds)
25-07-07 System Timers for VRS/DISA - Long Conversation
Warning Tone Time
30 (seconds)
25-07-08 System Timers for VRS/DISA - Long Conversation Dis-
connect Time
15 (seconds)
81-01-03 COT Initial Data Setup - Clear Signal (Open Loop) De-
tection Time
59 (295ms)
Method C - Tandem Trunking on Hang up
Program
Number
Program Name Default
14-01-04 Basic Trunk Data Setup - Transmit Gain Level for Con-
ference and Transfer Calls
32 (0dB)
14-01-05 Basic Trunk Data Setup - Receive Gain Level for Con-
ference and Transfer Calls
16 (-8dB)
14-01-13 Basic Trunk Data Setup - Trunk-to-Trunk Transfer 0
14-02-12 Analog Trunk Data Setup - Detect Network Disconnect
Signal
0
20-06-01 Class of Service for Extensions All extension port = Class 1