EasyManuals Logo

Neoway N11 V2 User Manual

Neoway N11 V2
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
N11 V2
AT Command Manual
Copyright © Neoway Technology Co., Ltd
115
0: Zero time zone
< DST >: Daylight Saving Time
1: Select DST auto-adjustment
0: Not select (by default)
Return Value
No PPP Link
Time Updating,Please Wait...
Time Out
Time Data Is Null
Send Request Fail
Update To yyyy-mm-dd,hh:mm:ss
Last Update Time yyyy-mm-dd,hh:mm:ss
Domain Name Invalid
Socket Error
Example
AT+UPDATETIME=0
+UPDATETIME: Last Update Time 2014-03-
31,11:10:26
OK
Query when the time was
updated last time.
AT+UPDATETIME=0
+UPDATETIME: Last Update Time 0000-00-
00,00:00:00
OK
Query when the time was
updated last time.
The time was not updated.
AT+UPDATETIME=1, 210.72.145.44,10
+UPDATETIME: No PPP Link
Set up a PPP link.
AT+UPDATETIME=1, 210.72.145.44,10
OK
Time Updating,Please Wait...
+UPDATETIME: Time Out
Update the time to that of
the server 210.72.145.44.
Timeout period is 10
seconds.
East time zone 8 by default
No DST
Time update times out
because of network
congestion.
AT+UPDATETIME=1,128.138.141.172,10,"E8",0
OK
Time Updating,Please Wait...
Update the time to that of
the server
128.138.141.172.
Timeout period is 10
seconds.