NIBE FIGHTER 1250
Menu 8.2.3 Allow electric heat [E]
To select if the electric addition is to be permitted during
room heating in operating mode Auto.
Selection option Off and On.
- Factory setting: Off
Menu 8.2.4 Return [E]
Pressing the enter button returns you to Menu 8.2.0
Menu 8.3.0 Current limiter [E]
Settings and readings regarding the load monitor are set
on the sub-menus to this menu.
Menu 8.3.1 Current phase 1 [E]
Shows the measured current from phase 1. If the value falls
below 2.0 A “low” is shown.
Menu 8.3.2 Current phase 2 [E]
Shows the measured current from phase 2. If the value falls
below 2.0 A “low” is shown.
Menu 8.3.3 Current phase 3 [E]
Shows the measured current from phase 3. If the value falls
below 2.0 A “low” is shown.
Menu 8.3.4 Fuse size [E]
The setting selected on the EBV card (2) knob (100) is
shown here.
Menu 8.3.5 Max elec. step [E]
The setting selected on the EBV card (2) knob (101) is
shown here.
Menu 8.3.6 EBV value [E]
The transfer value must be defi ned depending on the cur-
rent transformers used for the EBV card.
The value can be set between 100 and 600 in increments
of 5.
- Factory setting: 300
Menu 8.3.7 Return [E]
Pressing the enter button returns you to Menu 8.3.0
Menu 8.4.0 Pool adjustments [N]
Current pool temperature is displayed here.
(activated in menu 9.2.10)
Menu 8.4.1 Pooltemp./Setting [E]
The stop temperature for pool heating is selected here.
The value is adjustable between 5 and 55 °C
- Factory setting: 20 °C
Menu 8.4.2 Diff. Pool/min-temp [E]
The difference from the value in menu 8.4.1 when pool
heating starts is stated here.
The value is adjustable between 0.5 and 9.5 °C
- Factory setting: 1.5 °C
Menu 8.4.3 Pool time [E]
The maximum time for pool heating is selected here, for
more than one heating demand.
The value is adjustable between 5 and 60 minutes.
- Factory setting: 20 min
Menu 8.4.4 Comp speed pool [E]
The compressor frequency for pool heating is selected here.
The value is adjustable between 30 and 120 Hz.
- Factory setting: 60 Hz
Menu 8.4.5 Circ-pump speed pool [E]
The speed of the circulation pump during pool heating is
selected here.
The value is adjustable between 1 and 100 %
- Factory setting: 50 %
Menu 8.4.6 Pool heating [E]
Settings whether pool heating should be “On” or “Off”.
Selection option Off and On.
- Factory setting: Off
Menu 8.4.7 Pool run time [E]
Shows accumulated pool time.
Menu 8.4.8 Return [E]
Pressing the enter button returns you to Menu 8.4.0.
Menu 8.5 Return [N]
Pressing the enter button returns you to Menu 8.0.
Control
E