APPENDIX
TABLE 2 – ELECTRICAL INPUT/OUTPUT TABLE
MAIN CONTROL BOARD
Ladder Diagram: 56111804 Main PCB Assembly: 56111781
Main (Control) PCB: 56111782 Main PCB Schematic: 56111783
Pin ID
* = no connec-
tion on Rev C
Board
Designa-
tion
Pin As-
signment
Signal Char-
acteristic
Nominal
Voltage at
Connec-
tor (when
activated)
Refer-
ence
To:
Load Or Sup-
ply Charac-
teristics
Comments
J1-1 Input Engine Run
Digital Volt-
age
0V (for Gas/
Propane);
B+ (for
Diesel)
B-
Engine Control
Module Output
Switch to ground, ground = run,
oat = not running (for Gas/
Propane); Switch to Vbat (for
Propane)
J1-2 CANbus CANL Canbus (-) 0-5V J1-3
Differential
Serial Data
User interface panel serial com-
munication
J1-3 CANbus CANH Canbus (+) 0-5V J1-2
Differential
Serial Data
User interface panel serial com-
munication
J1-7 Input
Fuel Level
Sensor
(gas and
diesel)
Variable
Resistance
0.40-1.66V B-
Variable
Resistance to
Ground, 33-
240 ohms
Nominal voltage provided is
subject to change if additional
resolution is required
J1-10 5V output
Throttle
Position
(3.3V-A)
3.3v-A +3.3V B-
Pedal Position
Potentiometer
End 5K ohm
Drive pedal sensor High side
J1-11
Ground
Output
Throttle
Position
Ground
Ground 0V B-
Pedal Position
Potentiometer
End 5K ohm
Drive pedal sensor Low side
J1-12 Input
Ignition
Input Volt-
age
Analog Volt-
age
B+ B-
System Volt-
age
From key switch Ignition position
J1-16 Input
Horn
Switch
Digital Volt-
age
0V B-
Switch to
Ground
Push button switch - ground or
open - closed to activate horn
J1-18 Ground Ground Ground 0V B- Ground
J1-19 Input
Hydraulic
Fluid Temp
Variable
Resistance
0.16-2.24V B-
Variable
Resistance to
Ground, 12-
500 ohms
J1-20 Input
Brake
Pedal
Switch
Digital Volt-
age
0V B-
Switch to
Ground
Closes when brake pedal
released
J1-21 Input
Solution
Empty
Switch
Digital Volt-
age
0V B-
Switch to
Ground
Ground or open, closes when
tank is empty
J1-22 Output Start Inhibit
Low Side
Driver
0V B-
MOSFET Gate
On Relay
PCB Assy. - 3
Ma@12V
Ground or oat
J1-24 Input
Start KEY-
POS Switch
Digital Volt-
age
B+ B-
System Volt-
age
From key switch
J1-25 Input
Check
Engine
Switch
Digital Volt-
age
0V B-
Engine Control
Module Low
Side Output
Switch to ground,

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Condor XL and is the answer not in the manual?

Nilfisk-Advance Condor XL Specifications

General IconGeneral
BrandNilfisk-Advance
ModelCondor XL
CategoryFloor Machine
LanguageEnglish

Related product manuals