8-10 Troubleshooting
Figure 8-2 Scale Dip Switch Configuration
" NOTE The scale can also be tested from the FmXP Terminal Mode. See instructions below.
To test the scale from the FmXP terminal mode:
1. From the FmXP Main Window, select
Tools.
2. From the Tools menu, click on
Terminal and then on Scale .
3. VERY CAREFULLY use the following commands to check the scale responses:
! ESC P (escape key and capital P) Outputs the current scale value to the terminal screen.
! ESC S (escape key and capital S) Restarts the scale, but gives no response.
! ESC T (escape key and capital T) Tares and Re-zeroes the scale.
4. If the scale responds to these commands then there may be a software configuration issue.
Verify the scale is configured from the configuration menu. The scale type selected should be
SART-WZ (Figure 8-3). For detailed instructions, refer to the Fluidmove User Guide or
Online Help.