EasyManua.ls Logo

Olympus EVOLT E-500 - Power Supply; Operating Environment

Olympus EVOLT E-500
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
197
Information
12
Information
Exposure mode : (1) AUTO: Full auto
(2) P: Program AE(Program shift can be performed)
(3) A: Aperture priority AE
(4) S: Shutter priority AE
(5) M: Manual
ISO sensitivity : 100 - 400 (High ISO values (800 - 1600) are available)
Exposure compensation : Exposure can be adjusted in 1/3, 1/2 or 1 EV step within a
range of ± 5 EV.
White balance
Product type : CCD
Mode setting : Auto, Preset WB (7 settings), Customized WB ,
One-touch WB
Recording
Memory : CF card (Compatible with Type I and II)
Microdrive (Compatible with FAT 32)
xD-Picture Card
Recording system : Digital recording, TIFF (non-compression), JPEG (in
accordance with Design rule for Camera File system (DCF)),
RAW Data
Applicable standards : Exif 2.2, Digital Print Order Format (DPOF), PRINT Image
Matching
III
, PictBridge
Playback
Playback mode : Single-frame playback, Close-up playback, Index display,
Image rotation, Slideshow, Light box display, Calendar display
Information display : Information display, Histogram display
Drive
Drive mode : Single-frame shooting, Sequential shooting, Self-timer,
Remote control
Sequential shooting : 2.5 frames/sec. (Max. no. of storable sequential pictures:
4 frames in RAW/TIFF)
Self-timer : Operation time: 12 sec., 2 sec.
Optical remote control : Operation time: 2 sec., 0 sec. (instantaneous shooting) (RM-1
Remote Control (optional))
Flash
Synchronization : Synchronized with the camera at 1/180 sec. or less
Flash control mode : TTL-AUTO (TTL pre-flash mode), AUTO, MANUAL
External flash attachment: Hot shoe
External connector
USB connector/Multi-connector
Power supply
Battery : BLM-1 Li-ion Battery x1/CR123A lithium battery x3 (for use
with LBH-1 Lithium Battery Holder)
Dimensions/weight
Dimensions : 129.5 mm (W) x 94.5 mm (H) x 66 mm (D) (5.1" x 3.7" x 2.6")
(excluding protrusions)
Weight : Approx.435 g (1.0 Ib.) (without battery)
Operating environment
Temperature : 0 - 40°C (32°F - 104°F) (operation)/
-20 - 60°C (-4°F - 140°F) (storage)
Humidity : 30 - 90 % (operation)/10 - 90 % (storage)
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT ANY NOTICE
OR OBLIGATION ON THE PART OF THE MANUFACTURER.
s0004_e_Advanced.book Page 197 Tuesday, September 27, 2005 4:15 PM