102
CS/CJ/NSJ Series Instructions Reference Manual (W474)
2. Summary of Instructions
7-SEGMENT DIS-
PLAY OUTPUT
7SEG
214
(CS/CJ-series
CPU Unit Ver. 2.0
or later and CJ2
CPU Units only)
Converts the source data (either 4-digit or 8-digit BCD) to 7-segment
display data, and outputs that data to the specified output word.
Output
Required
822
ANALOG INPUT
DIRECT CON-
VERSION (for
CJ1W-AD042)
AIDC
@AIDC
216
Reads the input conversion value of the specified analog input number
from the CJ1W-AD042 Analog Input Unit in Direct Conversion Mode.
Output
Required
826
ANALOG OUT-
PUT DIRECT
CONVERSION
(for CJ1W-
DA042V)
AODC
@AODC
217
Outputs the output set value for the specified analog output number to
the CJ1W-DA042V Analog Output Unit in Direct Conversion Mode.
Output
Required
829
PCU HIGH-
SPEED POSI-
TIONING
NCDMV
@NCDMV
218
(CJ1W-NC@@4 or
CJ1W-NC@81,
CJ2H CPU Unit
Ver. 1.3 or later,
and CJ2M only)
Starts absolute or relative high-speed point-to-point positioning for the
specified axis of a CJ1W-NC@@4 or CJ1W-NC@81 Position Control
Unit.
Output
Required
832
PCU POSITION-
ING TRIGGER
NCDTR
@NCDTR
219
(CJ1W-NC@81,
CJ2H CPU Unit
Ver. 1.3 or later,
and CJ2M only)
Starts a sequence for Memory Operation of a CJ1W-NC@81 Position
Control Unit when the start condition for the sequence is waiting for a
command from NCDTR(219).
Output
Required
836
Instruction
Mnemonic
Code
Symbol/Operand Function Location
Execution
condition
Page
7SEG (214)
S
O
C
D
S: 1st source
word
O: Output word
C: Control data
D: S
stem word
AIDC(216)
N
A
N: Unit number
A: Analog input
number
AODC(217)
N
A
N: Unit number
A: Analog output
number
NCDMV(218)
C
A
C: Control word
A: First word of
Direct Operation
Command Area
NCDTR(219)
C
C: Control word