720
High-speed Counter/Pulse Output Instructions Section 3-20
For range comparison, the comparison table always contains eight ranges.
The table is 40 words long, as shown below. If it is not necessary to set eight
ranges, set the interrupt task number to FFFF hex for all unused ranges.
Note Always set the upper limit greater than or equal to the lower limit for any one
range.
Operand Specifications
TB+1
TB+2
TB+3
TB
0
15
03478
000 0000
11121415
TB+142
TB+143
TB+144
Lower word of target value 1
Upper word of target value 1
Interrupt task number for target value 1
00000000 to FFFFFFFF hex
00000000 to FFFFFFFF hex
Number of target values
0001 to 0030 hex (1 to 48 target values)
Interrupt Task Number
Interrupt task number
00 to FF hex (0 to 255)
Direction
OFF: Incrementing,
ON: Decrementin
g
Lower word of target value 48
Upper word of target value 48
Interrupt task number for target value 48
TB
TB+1
TB+2
TB+3
0
15
TB+35
TB+36
TB+37
TB+38
TB+39
Lower word of range 1 lower limit
Upper word of range 1 lower limit
Lower word of range 1 upper limit
Upper word of range 1 upper limit
Range 1 interrupt task number
0000 0000 to FFFF FFFF hex (See note.)
0000 0000 to FFFF FFFF hex (See note.)
0000 0000 to FFFF FFFF hex (See note.)
0000 0000 to FFFF FFFF hex (See note.)
Interrupt task number
0000 to 00FF hex: Interrupt task number 0 to 255
AAAA hex: Do not execute interrupt task.
FFFF hex: I
g
nore the settin
g
s for this ran
g
e.
Lower word of range 8 lower limit
Upper word of range 8 lower limit
Lower word of range 8 upper limit
Upper word of range 8 upper limit
Range 8 interrupt task number
Area P C TB
CIO Area --- --- CIO 0 to CIO 6143
Work Area --- --- W0 to W511
Holding Bit Area --- --- H0 to H511
Auxiliary Bit Area --- --- A448 to A959
Timer Area --- --- T0000 to T4095
Counter Area --- --- C0000 to C4095
DM Area --- --- D0 to D32767
Indirect DM addresses
in binary
--- --- @ D0 to @ D32767
Indirect DM addresses
in BCD
--- --- *D0 to *D32767