922
Clock Instructions Section 3-26
Variations
Applicable Program Areas
Operands C through C+2: Calendar Data
Set the calendar data in C through C+2 as shown in the following diagram.
T and T+1: Time Data
Set the time data in T and T+1 as shown in the following diagram.
Variations Executed Each Cycle for ON Condition CSUB(731)
Executed Once for Upward Differentiation @CSUB(731)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification Not supported.
Block program areas Step program areas Subroutines Interrupt tasks
OK OK OK OK
15 8 07
C
15 8 07
C+1
15 8 07
C+2
Minutes: 00 to 59 (BCD)
Seconds: 00 to 59 (BCD)
Day: 01 to 31 (BCD)
Hour: 00 to 23 (BCD)
Year: 00 to 99 (BCD)
Month: 01 to 12 (BCD)
15 8 07
T
15 0
T+1
Seconds: 00 to 59 (BCD)
Minutes: 00 to 59 (BCD)
Hours: 0000 to 9999 (BCD)