124
Configuring the Master
Section 6-4
CX-Server Up on pressing the Configure button, CX-Server is launched and displays the
CX-Server User Interface as shown below.
Configuring CX-Server In order to configure CX-Server for communication with the Unit, perform the
following procedure.
1,2,3...
1. Select the type of PLC to which the Unit is attached, from the Device Type
drop down selection box.
2. Press the Settings button next to the PLC type selected. The PLC settings
window (see figure below) is displayed.
3. In this window make the proper adjustments if necessary. The selections
made, must match the physical configuration of the PLC system. When
done, press the OK button.
4. Select the Network Type to be used as connection between the PC and
the Unit. The available options may include other PLC systems or Commu-
nication Units, which are setup to act as a gateway. Refer to
CX-Server
Runtime User Manual (W391)
for details on configuring CX-Server.
Note 1) For further explanation, only the direct connections between the
PC and the PLC on which the Unit is attached are considered.
These include ToolBus and SYSMAC WAY.