Loading...
Inspecting with the Edge Pitch Inspection Item
FQ2 User’s Manual
4
Setting Up Inspections
135
If there is an edge and it cannot be detected, adjust the [Noise level] on the [Details] Tab Page and try
teaching again.
If an edge is not detected when teaching, 0 will be registered as the reference width. If the result is OKed when
there is not edge, set the judgement parameters for a reference position of 0.
Edge Not Found
The measured edge pitch will be 0. Perform the following.
If a color was specified, make sure the color of the measurement object has not changed from the specified
color.
Set the color again if necessary.
If there is an edge and it cannot be detected, make sure the [Edge level] parameter on the [Details] Tab Page
is correct.
Edge level: p. 122