Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
274
FQ2 User’s Manual
Clearing an Error
This command clears the error output status.
Parameters
Timing Chart
Execution Command Input example
IN7 IN6 IN5 IN4 IN3 IN2 IN1 IN0
1 1000001 11000001
ON for 1 ms min.
OR signal
OFF
ON
BUSY signal
OFF
ON
OFF
ON
RUN signal
OFF
ON
TRIG signal
OFF
ON
Run Mode entered. Setup Mode entered.
D signals
Measurements executed.
GATE signal
OFF
ON
OFF
ON
Output timeGATE ON delay
ERROR signal
OFF
ON
OFF
ON
OFF
ON
IN0 to IN6
signals
IN7 signal
OFF
ON
Data
TRIG is input.
ACK signal
ACK output time
1000001
Allow 5 ms min. and then turn ON IN7.
ON for 1 ms min.