Page #457 background imageLoading...
Page #457 background image
External Reference Parameters
FQ2 User’s Manual
455
Appendices
12
121 Model
region
Rotation Setting/Acqui-
sition
0: No rotation 1: Rotation 0 --- ---
122 Rotation angle upper
limit
Setting/Acqui-
sition
−180 to 180 180 --- ---
123 Rotation angle lower
limit
Setting/Acqui-
sition
−180 to 180 −180 --- ---
134 Mea-
sure-
ment
condi-
tions
Sub-pixel Setting/Acqui-
sition
0: No, 1: Yes 0 --- ---
135 Candidate level Setting/Acqui-
sition
0 to 100 70 --- ---
136 Judge-
ment
condi-
tions
Judgement upper limit
for search coordinate X
Setting/Acqui-
sition
−99,999.9999 to
99,999.9999
99,999.9999 --- Adjust judge-
ment
137 Judgement lower limit
for search coordinate X
Setting/Acqui-
sition
−99,999.9999 to
99,999.9999
−99,999.9999 --- Adjust judge-
ment
138 Judgement upper limit
for search coordinate Y
Setting/Acqui-
sition
−99,999.9999 to
99,999.9999
99,999.9999 --- Adjust judge-
ment
139 Judgement lower limit
for search coordinate Y
Setting/Acqui-
sition
−99,999.9999 to
99,999.9999
−99,999.9999 --- Adjust judge-
ment
140 Judgement upper limit
for search angle
Setting/Acqui-
sition
−180 to 180 180 --- Adjust judge-
ment
141 Judgement lower limit
for search angle
Setting/Acqui-
sition
−180 to 180 −180 --- Adjust judge-
ment
142 Judgement upper limit
for correlation
Setting/Acqui-
sition
0 to 100 100 --- Adjust judge-
ment
143 Judgement lower limit
for correlation
Setting/Acqui-
sition
0 to 100 60 --- Adjust judge-
ment
145 Density deviation upper
limit
Setting/Acqui-
si
tio
n
Color Cameras: 0 to 221
Monochrome Cameras: 0
to 127
Color Cam-
era: 221
Monochrome
Camera: 127
--- Adjust judge-
ment
146 Density deviation lower
limit
Setting/Acqui-
sition
Color Cameras: 0 to 221
Monochrome Cameras: 0
to 127
0 --- Adjust judge-
ment
147 NG sub-region upper
limit
Setting/Acqui-
sition
0 to 100 100 --- ---
148 NG sub-region lower
limit
Setting/Acqui-
sition
0 to 100 0 --- ---
153 Mea-
sure-
ment
condi-
tions
Plain inspection Setting/Acqui-
sition
0: No, 1: Yes 0 --- ---
169 Gain setting Setting/Acqui-
sition
0: 3×3 sub-divisions, 1: 5×5
sub-divisions, 2: 9×9 sub-
divisions
1 --- ---
310 Logging
condi-
tions
Data logging switch for
entire unit
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1 --- ---
311 Data logging switch for
judgement
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1 --- ---
312 Data logging switch for
correlation
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1 --- ---
313
Data logging switch
for density deviation
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1 --- ---
External
refer-
ence
number
Category Data name Setting/Acqui-
sition
Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fq2 and is the answer not in the manual?

Omron fq2 Specifications

General IconGeneral
BrandOmron
Modelfq2
CategoryDigital Camera
LanguageEnglish

Related product manuals