Setting Up Ethernet
FQ2 User’s Manual
2
Installation and Connections
55
Connections on Existing Networks
Set the Ethernet settings of the Sensors and the computer (PC Tool) to the same settings as the existing
network. Refer to Connecting to Sensors from the Touch Finder on page 53 for the IP address settings in the
Sensors.
4 On the [General] Tab Page, double-click Internet Proto-
col (TCP/IC).
5 Select the Use the following IP address Option and en-
ter the following IP address and subnet mask.
IP address: 10.5.5.101
Subnet mask: 255.255.255.0
6 Click the [OK] Button. This completes the settings.
If you connect the PC Tool to a Sensor on a different network through a router, set fixed IP addresses.
If you use an EtherNet/IP connections, set fixed IP address for the Sensors.