Section 2 NS Series Functions 2-20 Special Functions
2-491
NS Series Programming Manual
1
2
5
3
4
No. Item Description
1 Addresses The word to be sampled is displayed.
To change or delete the settings, click the No. Button and select the bit.
2 Word set-
tings
Edit the word to be sampled.
Click the Up or Down Buttons to change the type. Words can be set in the following areas: CIO,
Work, Auxiliary, Timer, Counter, DM, current EM bank, and EM banks 0 to 18 hex.
The ten-key will be displayed when the address display area is clicked. Enter the address to be
monitored. Addresses 0 to 32,767 can be set, but enter a value that is within the address range
of the area in the PLC to be connected.
3 Settings Sets the specified word address in the address list.
4 Delete Deletes the specified address from the address list.
5 Trace data
size
Sets whether to sample the specified address as 1-word data or 2-word data.
N
N
N
o
o
o
t
t
t
e
e
e
♦
Be sure to click the Set Button to add the specified address to the address list.
Setting the Bit Addresses
The Bit Address Setting Tab Page sets the bit addresses of the bits to be sampled.
1. Open the Data Trace Configuration Screen’s Bit Address Setting Tab Page.
3
4
2
1
No. Item Description
1 Address List Displays the bit address of the bit to be sampled.
When changing or deleting a setting, press the No. Button and select the bit.

Table of Contents

Other manuals for Omron NS10-TV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NS10-TV Series and is the answer not in the manual?

Omron NS10-TV Series Specifications

General IconGeneral
BrandOmron
ModelNS10-TV Series
CategoryTouch terminals
LanguageEnglish

Related product manuals