Inverter Protection
6-51
Related Parameters
Soft CLA Selection
Soft CLA (software current level A) is a current detection level for the output IGBT protection. It is only
active during acceleration and lowers the output voltage quickly to reduce the current in order to protect the
IGBTs.
The Soft CLA function can be disabled by setting parameter L8-18 to 0. Generally it is absolutely not recom-
mended to disable this function.
Related Parameters
Parameter
Number
Name
Setting
Range
Factory
Setting
Change
during
Operation
Access
Level
L8-15 OL2 characteristics selection at low speeds 0 or 1 1 No A
Parameter
Number
Name
Setting
Range
Factory
Setting
Change
during
Operation
Access
Level
L8-18 Soft CLA selection 0 or 1 1 No A