102
Section 5 Entering Threshold Values
ZX-E
Operation Manual
Section 5
DETAILED SETTINGS
Hysteresis Setting
Set the hysteresis width for the upper and lower limits of judgements when the HIGH,
PASS, or LOW judgements are unstable near the threshold values.
Hysteresis width settings are disabled when previous value comparison is used.
p. 80
To prevent self-trigger chattering, set hysteresis for the self-trigger.
p. 83
Moving to FUN Mode and HYS
1. Set the mode switch to FUN.
2. The main display will show HYS.
3. Press the UP or DOWN Key.
The leftmost of the sub-display will flash.
4. Use the Cursor Keys to enter the hysteresis
width.
5. Press the ENT Key to confirm the setting.
The hysteresis width will be registered.
Countermeasures for Setting Errors
If ERROV is displayed, HIGH threshold value
− LOW
threshold value < hysteresis width.
If an error is displayed, the threshold values have not
been updated. Set the values again or change the
threshold values.
Operating valu
Release value
HIGH threshold value
Measured value
LOW threshold value
Hysteresis (hysteresis width)
Output
Move between digits.
Increment and decre-
ment the numeric value.
Z166-E1-02A.book Page 102 Friday, June 3, 2005 4:18 PM