Section 5 Using Hold Functions
Section 5
DETAILED SETTINGS
Using Hold Functions
The hold functions hold data for specific points during the measurement period, such as the
maximum or minimum value, and output those values at the end of the measurement period.
❚ Flow of Operation
Selecting Hold Condition for Measured Values
The time period from the start of hold measurements to the end of hold measurements
is called the sampling period.
The value to be held during that sampling period is selected here.
The CLAMP value is output until the first sampling period is finished.
CLAMP value, p. 110
Any of the 5 settings shown in the table can be selected as the value to hold.
3
2
1
Selecting Hold Condition
for Measured Values
Setting the Trigger for
Measurement in Hold
Mode
Setting Delay Time
(If required)
Selection Details
OFF
(Default)
Hold measurement is not performed. The measured value is always output.
P-H (Peak hold) Holds the maximum value during the sampling period. The output changes when
the sampling period is finished and is held then until the end of the next sampling
period.
B-H (Bottom hold) Holds the minimum value during the sampling period. The output changes at the
end of the sampling period and is held until the end of the next sampling period.
Current meas-
ured value
Maximum
value
Output
Sam
lin
eriod
Minimum
value
Current meas-
ured value
Output
Sampling period