ZX-E
Operation Manual
Section 6 Initializing Settings Data
Section 6
AUXILIARY FUNCTIONS
Initializing Settings Data
This function resets all settings to their default values.
Linearity adjustments, however, are not initialized using this function. To initialize linearity adjustment
data, perform initialization in linearity adjustment mode.
Initializing Adjustment Settings, p. 59
Function Default Value
No. of samples to average 64
Hysteresis width The default differs depending on the connected Sensor Head.
ZX-EDR5T: 0.0003
ZX-ED01T: 0.0004
ZX-ED02T: 0.0008
ZX-EM02T: 0.0008
ZX-EM07MT: 0.003
ZX-EV04T: 0.0016
ZX-EM02HT: 0.0008
Hold OFF
Timer OFF
Special functions CLOSE
Scaling OFF
Monitor focus At 0 mm: 4 (mA)
At rated measurement distance: 20 (mA)
Linear output correction No correction
Display reverse OFF
ECO display OFF
No. of display digits 5 digits (all)
Non-measurement settings KEEP
Zero reset memory ON
HIGH threshold The default differs depending on the connected Sensor Head.
ZX-EM07MT: 59.999 (mm)
Other Sensor Heads: 5.9999 (mm)
LOW threshold The default differs depending on the connected Sensor Head.
ZX-EM07MT: 19.999 (mm)
Other Sensor Heads: 1.9999 (mm)