58
Section 3 Adjusting Linearity
ZX-E
Operation Manual
Section 3
BASIC OPERATION
Executing Adjustment
This section describes how to execute adjustment based on the settings made in steps
and .
Executing Adjustment
1. Use the LEFT and RIGHT Keys to display
TABLE on the main display and START on the
sub-display.
2. Press the ENT Key.
Linear adjustment will be executed.
When the adjustment data has been registered, the sub-
display will show OK.
If the sub-display shows ERRTB, there has been a mis-
take in the settings. Check the material selected for the
sensing object and the set positions and register the set-
tings again.
Cancelling Adjustment
The adjustment settings will be cleared if the adjustment is cancelled.
1. Use the LEFT and RIGHT Keys to display
TABLE on the main display and CANCL on
the sub-display.
2. Press the ENT Key.
The settings for the current adjustment will be cancelled
and the display will change to LINER.
OK
NG