Section 4 Measuring Eccentricity and Vibration
Section 4
MAIN APPLICATIONS AND SETTING METHODS
Measuring Eccentricity and Vibration
This section describes, as an example, how to measure the eccentricity of a shaft.
When making settings while still connected to an external device, set the Amplifier Unit’s judgement output
hold input to ON so that the output to the external device remains unchanged.
Adjust linearity before performing this operation.
Adjusting Linearity, p. 54
Flow of Operation
Metal shaft
Mounting to
Device
Adjusting
Measurement
Distances
Setting Tolerance
Judgment Values
Measuring
Deflection
Z166-E1-02A.book Page 71 Friday, June 3, 2005 4:18 PM