Installing Sensor Heads
This section describes how to install Sensor Heads and Preamplifiers.
Sensor Heads
Installation
ZX-ED@@T Sensor Heads (Non-threaded Type)
When using a set screw, tighten the screw to a torque of 0.2 Nm or less.
Mount the Sensor Head as shown in the following diagram.
ZX-EM@@T Sensor Heads (Threaded Type)
The tightening torque for the threaded type (ZX-EM@@T) is shown in the following
table.
When using the ZX-EM02HT, consider the thermal expansion caused by the rise in temperature
of the sensing object, and make sure that the sensing object does not touch the sensing surface.
Even when operated within the specified temperature range, using in locations subject to
extreme temperature fluctuations may result in deterioration of Sensor characteristics.
When using the ZX-EM02HT, make sure that the bending radius of the cable from the Sensor
Head is 8 mm or greater .
Mounting Bracket (order separately)
Y92E-F5R4 (for 5.4 mm dia.)
Set screw hole
Model A
ZX-EDR5T 9 to 18
ZX-ED01T 9 to 18
ZX-ED02T 11 to 22
(Unit: mm)
Model
Strength
(torque)
ZX-EM02T
15 N·m
ZX-EM07MT
ZX-EM02HT 5.9 N·m