Section 4 Measuring Height
ZX-E
Operation Manual
Section 4
MAIN APPLICATIONS AND SETTING METHODS
Measuring Reference Samples
The height of the reference sample is measured using position teaching and the mea-
surement result is registered as the HIGH threshold value.
The registered value becomes the reference for the threshold value set in step .
Refer to Section 5 Detailed Settings for details on settings.
Position Teaching, p. 99
The reference sample height can also be set to 0.
Using the Zero Reset Function, p. 127
Setting Tolerance Judgement Values
Refer to the HIGH threshold registered in step and set the upper and lower limits
(HIGH and LOW thresholds) for a PASS (OK) judgement.
The HIGH, PASS, and LOW judgement results will be output based on the threshold
values set here.
Refer to Section 5 Detailed Settings for details on operation.
Inputting Threshold Values Directly, p. 98
Measurement result Judgement
Measurement result > HIGH threshold HIGH
LOW threshold
≤ measurement result ≤ HIGH threshold PASS
LOW threshold > measurement result LOW