EasyManua.ls Logo

Omron ZX-E - Page 143

Omron ZX-E
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
141
ZX-E
Operation Manual
Appendices
Specifications and Dimensions
APPENDICES
Notes: 1. The response speed of the linear output is calculated as the measurement period x (No. of samples to
average setting + 1).
The response speed of the judgement outputs is calculated as the measurement period x (No. of samples
to average setting + 1).
2. The output can be switched between current output and voltage output using a switch on the bottom of the
Amplifier Unit.
3. Setting is possible via the monitor focus function.
4. A Calculating Unit is required.
Functions Measured value
display
Present value dis-
play
Output value dis-
play
Set value display
Resolution display
ENABLE indicator
Zero reset indica-
tor
Power ON indica-
tor
Judgement indica-
tor
ECO mode
Display reverse
Display digit limit
Zero reset
Zero reset memory
Previous value compari-
son
Initialization
Linearity initialization
Teaching
Direct threshold value
setting
Hysteresis width setting
Scaling
Linearity adjustment
Monitor focus
Linear output correc-
tion
Peak hold
Bottom hold
Sample hold
Peak-to-peak hold
Average hold
Delay hold
Delay time setting
ON-delay timer
OFF-delay timer
One-shot timer
Timing inputs
Self-up trigger
Self-down trigger
(A-B) calculations
(See note 4.)
(A+B) calculations
(See note 4.)
Thickness calculation
(See note 4.)
Mutual interference
prevention
(See note 4.)
Key lock
Clamp value setting
Indications Judgement indicators: HIGH (orange), PASS (green), LOW (yellow), 7-segment main display
(red), 7-segment sub-display (yellow), power ON (green), zero reset (green), enable (green)
Voltage influence
(including Sensor)
0.5% F.S. of linear output value at
±20% of power supply voltage
Power supply
voltage
12 to 24 VDC
± 10%, Ripple (p-p): 10% max.
Power consumption 3.4 W max. (Sensor connected)
(Power supply voltage: 24 V, Current consumption: 140 mA max.)
Ambient
temperature
Operating and storage: 0 to 50
°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Insulation
resistance
20 M
min. at 500 VDC
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destructive)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
Shock resistance
(destructive)
300 m/s
2
3 times each in six directions (up/down, left/right, forward/backward)
Connection method Prewired (standard cable length: 2 m)
Weight (packed
state)
Approx. 350 g
Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories Instruction sheet
ZX-EDA11 ZX-EDA41
Z166-E1-02A.book Page 141 Friday, June 3, 2005 4:18 PM