27
ZX-E
Operation Manual
Section 2 Part Names and Functions
Section 2
PREPARATIONS FOR MEASUREMENT
Interface Units
(1) The communications connector connects the communications cable to the computer.
(2) The Amplifier Unit connector connects to the Amplifier Unit.
(3) The power supply indicator lights when the power is turned ON.
(4) BUSY: Lights during communications with the Smart Sensor.
ERR: Lights if an error occurs during communications with the Smart Sensor.
(5) BUSY: Lights during communications with the personal computer.
ERR: Lights if an error occurs during communications with the computer.
Display ()
(1) Communications Connector
(2) Amplifier Unit Connector
(3) Power supply indicator
(4) Sensor communications indicators (BUSY and ERR)
(5) External terminal communications indicators (BUSY and ERR)
Display Detail
Z166-E1-02A.book Page 27 Friday, June 3, 2005 4:18 PM