75
ZX-E
Operation Manual
Section 4 Measuring Thickness
Section 4
MAIN APPLICATIONS AND SETTING METHODS
Mounting to Device
Connecting Amplifier Units
Connect two Amplifier Units by placing a Calculating Unit between them as shown in
the diagram.
The calculation result is displayed on (i.e., output to) the CH2 Amplifier Unit. Connect
the CH2 output cable to the external device to enable external control.
Connections, p. 34
The CH1 Amplifier Unit will display (output) the measurement result for the CH1 Sensor Head only.
Mounting Sensor Heads to Inspection Device
Refer to the following diagram and prepare mounting jigs. Mount the Sensor Heads fac-
ing each other.
Installing Sensor Heads, p. 30
Calculating Unit
Mounting jigs
(resin or metal)
Set screws