Locating a Failed Component (CLI)
1.
Go to the maintenance hardware context:
hostname:> maintenance hardware
2.
List the appliance components:
hostname:maintenance hardware> list
NAME STATE MODEL SERIAL
chassis-000 hostname ok Sun Storage 7320 unknown
chassis-001 000000000C faulted J4410 000000000C
3.
Select the chassis and list its components:
hostname:maintenance hardware> select chassis-001
hostname:maintenance chassis-001> list
disk
fan
psu
slot
4.
Select the component type and show all available disks:
hostname:maintenance chassis-001> select disk
hostname:maintenance chassis-001 disk> show
Disks:
LABEL STATE MANUFACTURER MODEL SERIAL
disk-000 HDD 0 ok ST3500630NS ST3500630NS 9QG1ACNJ
disk-001 HDD 1 faulted ST3500630NS ST3500630NS 9QG1A77R
disk-002 HDD 2 ok ST3500630NS ST3500630NS 9QG1AC3Z
disk-003 HDD 3 ok ST3500630NS ST3500630NS 9QG1ACKW
disk-004 HDD 4 ok ST3500630NS ST3500630NS 9QG1ACKF
disk-005 HDD 5 ok ST3500630NS ST3500630NS 9QG1ACPM
disk-006 HDD 6 ok ST3500630NS ST3500630NS 9QG1ACRR
disk-007 HDD 7 ok ST3500630NS ST3500630NS 9QG1ACGD
disk-008 HDD 8 ok ST3500630NS ST3500630NS 9QG1ACG4
disk-009 HDD 9 ok ST3500630NS ST3500630NS 9QG1ABDZ
disk-010 HDD 10 ok ST3500630NS ST3500630NS 9QG1A769
disk-011 HDD 11 ok ST3500630NS ST3500630NS 9QG1AC27
disk-012 HDD 12 ok ST3500630NS ST3500630NS 9QG1AC41
disk-013 HDD 13 ok ST3500630NS ST3500630NS 9QG1ACQ5
disk-014 HDD 14 ok ST3500630NS ST3500630NS 9QG1ACKA
disk-015 HDD 15 ok ST3500630NS ST3500630NS 9QG1AC5Y
disk-016 HDD 16 ok ST3500630NS ST3500630NS 9QG1ACQ2
disk-017 HDD 17 ok ST3500630NS ST3500630NS 9QG1A76S
Getting Started with Servicing the Hardware 35