2-48
INSTALLATION ORBAN MODEL 8685
tered, the 8685 will ignore the command.
You can apply this command anytime after the 8685 boots up. The 30-minute
timeout does not apply.
This command is useful in interfacing automation systems to the 8685.
2. To recall a Setup:
Command Response
RS XXXXXXX[PASSCODE]«
(valid passcode and Setup name)
ON AIR: XXXXXXX
(invalid passcode)
[no error message is issued]
In the above table: XXXXXXX = the Setup name;
PASSCODE = any valid passcode.
If a non-existent Setup name, control value, and/or an invalid passcode is en-
tered, the 8685 will ignore the command.
You can apply this command anytime after the 8685 boots up. The 30-minute
timeout does not apply.
This command is useful in interfacing automation systems to the 8685.
3. To restore factory defaults:
Command Response
RESTORE FACTORY DEFAULTS« Are you sure (yes/no)?«
YES«
(factory defaults restored)
Restored«
NO«
(or any response other than
YES«”)
(abort)
Defaults not restored«
To protect against accidental loss of settings, you must enter the entire com-
mand string and a “YES” response in uppercase.
Restoring factory defaults does the following:
Deletes all User Presets
Resets all global parameters to factory default settings
Deletes all Automation Events
Restores Remote Interface inputs 1-8 to “no function”