OPTIMOD SURROUND PROCESSOR INSTALLATION
2-49
4. To unlock an 8685:
The following command assigns an A
LL ACCESS passcode. This passcode is then
available from the front panel or when you connect normally via the 8685PC ap-
plication (through the 8685’s Serial Port #1 or optional Ethernet connections).
Command Response
PW ########«
(valid passcode entry) Accepted«
(invalid passcode entry) Denied«
Valid arguments follow the same rules for passcode entries made from the front
panel and via 8685PC:
• Passcode length must be 1 to 8 characters.
• Only alphanumeric characters are allowed (0…9 and A…Z). No punctuation or
extended characters are allowed.
• Lower case letters included in the argument will automatically be converted
to upper case.
5. To change the IP Address:
Command Response
IP XXX.XXX.XXX.XXX«
(valid IP address)
IP: xxx.xxx.xxx.xxx entered«
(invalid IP address)
ERROR. Using IP: yyy.yyy.yyy.yyy«
IP?« Using IP: yyy.yyy.yyy.yyy«
In the above table: XXX.XXX.XXX.XXX = the specified IP address;
yyy.yyy.yyy.yyy = the present (or default) IP address in
use.
192.168.254.254 is the factory default.
Any out-of-range or invalid characters render invalid the whole IP ad-
dress that you entered.
6. To change the Subnet Mask:
Command Response
SN XXX.XXX.XXX.XXX«
(valid subnet)
SN: xxx.xxx.xxx.xxx entered«
(invalid subnet)
ERROR. Using SN: yyy.yyy.yyy.yyy«
SN?« Using SN: yyy.yyy.yyy.yyy«