2-50
INSTALLATION ORBAN MODEL 8685
In the above table: XXX.XXX.XXX.XXX = the specified subnet mask;
yyy.yyy.yyy.yyy = the present subnet mask in use.
255.255.255.0 is the factory default.
Valid subnet masks are defined according to existing standards. Any out-of-
range or invalid characters render the whole argument invalid.
7. To change the Gateway:
Command Response
GW XXX.XXX.XXX.XXX«
(valid gateway)
GW: xxx.xxx.xxx.xxx entered«
(invalid gateway)
ERROR. Using gw: yyy.yyy.yyy.yyy«
GW?« Using GW: yyy.yyy.yyy.yyy«
In the above table: XXX.XXX.XXX.XXX = the specified gateway;
yyy.yyy.yyy.yyy = the present gateway in use.
Valid gateways are defined according to existing standards. Any out-of-range or
invalid characters render the whole argument invalid.
8. To change the Port:
Command Response
PO XXXXX «
(valid port)
PO: xxxxx entered«
(invalid port)
ERROR. Using PO: yyyyy«
PO?« Using PO: yyyyy«
In the above table: XXX.XXX.XXX.XXX = the specified port;
yyy.yyy.yyy.yyy = the present port in use.
Port 6201 is the factory default.
Valid ports are defined according to existing standards. Any out-of-range or in-
valid characters render the whole argument invalid.