Addresses and codes list
Conguration
Conguration can be executed when all of the following conditions are satised:
An alarm is not present
The motor is not operated
I/O test, teaching/remote operation, and download are not being performed with the
MEXE02
.
The table below shows the driver status before and after conguration is executed.
Item
Conguration is ready to
execute
Conguration is executing After conguration is executed
PWR/ALM LED Lit in green
Blink in orange
(Red and green colors may overlap and it may
be visible to orange.)
Lit in green
Output signals Allowed Not allowed Allowed
Input signals Allowed Not allowed Allowed
The correct monitor value may not return even if the monitor is executed while conguration is being executed.
12.5.1 How to execute the maintenance commands
To execute via Modbus communication
There are two types of execution methods. Use them selectively in accordance with the intended use.
z
Write "1" to data (Recommended)
Write "1" to data, and when the data changes from "0" to "1," the command is executed.
When executing the same command again, once return to "0," and write "1." It can be used with safety because the
command is not executed consecutively even if "1" is continued to write from the master controller.
z
Write "2" to data
If "2" is written to data, the command is executed. It will automatically return to "1" after the execution. The data can be
written consecutively because of no need to be returned to "0."
If commands which take time to write to the non-volatile memory such as "Write batch NV memory" command are
executed consecutively, increase the length of the intervals between commands.
Only the "Alarm history details" command is an exception. Write the alarm history number to be checked with the
"Alarm history details" of the monitor command.
The following maintenance commands may not be completed at the time of sending the response.
To check that a command is completed, check that the SYS-BSY has been turned from ON to OFF.
Conguration
Batch data initialization
All data batch initialization
Read batch NV memory
Write batch NV memory
12.6 Monitor commands
These commands are used to monitor the operation data, alarm and information histories, etc. All commands are read-
only.
Alarm related commands
These are monitor commands related to alarms.
Modbus communication
Register address
Name Description
Upper Lower
128
(0080h)
129
(0081h)
Present alarm Monitors the alarm code presently being generated.
130
(0082h)
131
(0083h)
Alarm history 1
Monitors the latest alarm history. When an alarm is being generated, the alarm
code presently being generated is indicated.