Parameter
9.6 Direct-IN function selection, Direct-OUT function selection
C: Update after executing Conguration
Parameter name Description Setting range Factory setting Update
D-IN0 input function selection
Selects the input signal to assign to
the direct I/O (D-IN0 to D-IN4).
Refer to p.58.
58: FWD (START/STOP)
*
C
D-IN1 input function selection 59: REV (RUN/BRAKE)
*
D-IN2 input function selection 72: STOP-MODE (FWD/REV)
*
D-IN3 input function selection 64: M0
D-IN4 input function selection 8: ALM-RST
D-IN0 input logic level setting
Sets the logic level for the direct I/O
(D-IN0 to D-IN4).
0: Not invert
1: Invert
0: Not invert
D-IN1 input logic level setting 0: Not invert
D-IN2 input logic level setting 0: Not invert
D-IN3 input logic level setting 0: Not invert
D-IN4 input logic level setting 0: Not invert
D-OUT0 output function selection
Selects the output signal to assign
to the direct I/O (D-OUT0, D-OUT1).
Refer to p.58.
147: SPEED-OUT
D-OUT1 output function selection 130: ALM-B
D-OUT0 output logic level setting
Sets the logic level for the direct I/O
(D-OUT0, D-OUT1).
0: Not invert
1: Invert
0: Not invert
D-OUT1 output logic level setting 0: Not invert
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be
applied.
9.7 Remote-IN function selection, Remote-OUT function selection
C: Update after executing Conguration
Parameter name Description Setting range Factory setting Update
R-IN0 input function selection
Selects the input signal to assign to
the remote I/O (R-IN0 to R-IN15).
Refer to p.58.
64: M0
C
R-IN1 input function selection 65: M1
R-IN2 input function selection 66: M2
R-IN3 input function selection 58: FWD (START/STOP)
*
R-IN4 input function selection 59: REV (RUN/BRAKE)
*
R-IN5 input function selection 72: STOP-MODE (FWD/REV)
*
R-IN6 input function selection 0: Not used
R-IN7 input function selection 8: ALM-RST
R-IN8 input function selection 0: Not used
R-IN9 input function selection 0: Not used
R-IN10 input function selection 0: Not used
R-IN11 input function selection 0: Not used
R-IN12 input function selection 0: Not used
R-IN13 input function selection 0: Not used
R-IN14 input function selection 0: Not used
R-IN15 input function selection 0: Not used
R-OUT0 output function selection
Selects the output signal to assign to
the remote I/O (R-OUT0 to R-OUT15).
Refer to p.58.
64: M0_R
R-OUT1 output function selection 65: M1_R
R-OUT2 output function selection 66: M2_R
R-OUT3 output function selection 58: FWD (START/STOP)_R
*
R-OUT4 output function selection 59: REV (RUN/BRAKE)_R
*
R-OUT5 output function selection 72: STOP-MODE (FWD/REV)_R
*
R-OUT6 output function selection 135: INFO
R-OUT7 output function selection 129: ALM-A
R-OUT8 output function selection 136: SYS-BSY
R-OUT9 output function selection 148: DIR
R-OUT10 output function selection 168: MPS
R-OUT11 output function selection 0: Not used
R-OUT12 output function selection 0: Not used
R-OUT13 output function selection 134: MOVE
R-OUT14 output function selection 141: VA
R-OUT15 output function selection 140: TLC
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be
applied.