EasyManua.ls Logo

Oriental motor BLH Series - Connection Diagram

Oriental motor BLH Series
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Connection
6.9 Connection diagram
A connection example of I/O signals with a programmable controller are as shown below.
The I/O signals circuit of the
BLH
Series RS-485 communication type are congured with current SINK logic. (Current
SOURCE logic is not supported.)
C-MOS
C-MOS
C-MOS
C-MOS
C-MOS
DriverController
11
10
9
8
7
3
2
1
3
10 k
10 k
10 k
10 k
10 k
D-IN0 (START/STOP)
D-IN1 (RUN/BRAKE)
D-IN2 (FWD/REV)
D-IN3 (M0)
D-IN4 (ALM-RST)
D-OUT0 (SPEED-OUT)
D-OUT1 (ALM-B)
GND
GND
0 V
0 V
0 V
5 VDC
0 V
4.5 to 26.4 VDC
R
R
10 mA or less
Note
Insulate unused lead wires which are on the opposite side to the connector of the I/O signal cable to prevent them
from contacting other devices, or connect them to 5 VDC or the signal ground (GND) of your external control device
according to usage of signals.
When extending the I/O signal cable, keep the length of 3 m (9.8 ft.) or less and wire in order to suppress noise
eects.
Be sure to suppress the current value of output signals to 10 mA or less. Connect a current limiting resistor R
externally if the current exceeds this specied value.

Table of Contents

Other manuals for Oriental motor BLH Series