Parameter
9.4 Alarm and information settings
Refer to p.137 for details about alarms.
Refer to p.141 for details about information.
A: Update immediately, C: Update after executing Conguration
Parameter name Description Setting range Factory setting Update
Overload alarm detection time
Sets the detection time of the overload
alarm.
0.1 to 10.0 s 10.0 A
Prevention of operation at power-on
alarm
Sets whether to enable or disable the
prevention of operation at power-on
alarm.
0: Disable
1: Enable
1 C
Information auto clear
This is a function to clear the
information status automatically when
the cause of the generated information
was removed.
0: Disable
1: Enable
1
A
Driver temperature information
Sets the condition in which the driver
temperature information is generated.
40 to 85 °C 85
Overvoltage information
Sets the condition in which the
overvoltage information is generated.
18.0 to 38.0 VDC 38.0
Undervoltage information
Sets the condition in which the
undervoltage information is generated.
18.0 to 38.0 VDC 18.0
Load information
Sets the condition in which the load
information is generated.
0: Disable
1 to 200%
0
Speed information
Sets the condition in which the speed
information is generated.
0: Disable
1 to 5200 r/min
0
RS-485 communication error
information
Sets the condition in which the RS-485
communication error information is
generated.
1 to 10 times 3
Tripmeter information
Sets the condition in which the
tripmeter information is generated.
0.0: Disable
0.1 to 99999999.9 kRev
0.0
Odometer information
Sets the condition in which the
odometer information is generated.
0.0: Disable
0.1 to 99999999.9 kRev
0.0
Main power supply time information
Sets the condition in which the main
power supply time information is
generated.
0: Disable
1 to 999999999 min
0
Main power supply count information
Sets the condition in which the main
power supply count information is
generated.
0: Disable
1 to 999999999 times
0
Rotation amount meter information
(positive side)
Sets the condition in which the rotation
amount meter information (positive
side) is generated.
−2147483648 to
+2147483647 rev
+2147483647
Rotation amount meter information
(negative side)
Sets the condition in which the rotation
amount meter information (negative
side) is generated.
−2147483648 to
+2147483647 rev
−2147483648