Operation data
7.3 Setting the acceleration time and deceleration time
The acceleration time and the deceleration time can be set so that an impact is not applied to a load when the motor is
started or stopped.
The actual acceleration time and deceleration time vary depending on the conditions of use, load inertia, or load torque
specied by the customer.
The acceleration time refers to a time needed for the motor to reach 3000 r/min from a standstill state.
The deceleration time refers to a time needed for the motor to stop from the 3000 r/min.
Setting method
Digital
Host
controller
Setting range: 0.1 to 15.0 s
(Factory setting: 0.5 s)
MEXE02
or RS-485 communication
[
MEXE02
Setting window of acceleration time and deceleration time]
7.4 Setting the torque limiting value
The maximum output torque of the motor can be limited.
Set when limiting the motor output torque according to a load.
TL input
When the TL input is assigned to the input terminal, enabling or disabling the torque limiting function can be switched
by the ON-OFF status of the TL input.
TL input Torque limiting Maximum output torque of motor
ON Enable The motor output torque is limited based on the set torque limiting value.
OFF Disable The motor output torque is the peak torque.
Note
When the TL input is not assigned to the input terminal, this input will be always set to ON. If the TL input is assigned
to multiple input terminals, the function will be performed when all of the terminals are turned ON.