Operation data
TLC output
When the motor output torque is limited, the TLC output is turned ON.
Note
If the motor is operated at low speed or the torque limiting value is set to less than 20%, the TLC output may not be
stable.
Setting method
Digital External analog setting device/PWM signal input
Host
controller
0 to 5 VDC
1 mA or more
MEXE02
or RS-485 communication External potentiometer External DC voltage PWM signal
The setting method for each operation data number can be changed using the
MEXE02
or RS-485 communication.
If the external analog setting device/PWM signal input is selected in the setting method, set whether to set the
operation data with the external analog setting device (external potentiometer, external DC voltage) or the PWM signal
input using the "External setting method" parameter.
Refer to p.36 when setting the upper limit of the torque limiting value.
Digital setting
Setting range: 0 to 200%
(Factory setting: 200%)
[
MEXE02
Setting window of torque limiting]