How to use MEXE02
13.5 Test operation
Teaching/remote operation
A motor can be operated using the
MEXE02
. The motor operation can be checked before connecting to a host
controller.
Also, the teaching function of the operation data can be performed.
The PWR/ALM LED on the driver blinks in orange when teaching/remote operation is started.
Note
•
Teaching/remote operation and I/O test cannot be executed at the same time.
•
While teaching/remote operation is performed, the motor is operated based on the data set in the teaching data.
If the motor is used in a state where the output torque is limited, check the setting of the teaching data before
performing teaching/remote operation.
1. Start "Teaching/remote operation."
2. Click "Start the teaching/remote operation."
3. Click "Yes."
Teaching/remote operation is enabled.
Teaching/remote operation requires synchronization of the data
under editing and the data of an applicable product. When the
data is not synchronized, the following window appears. Select a
synchronization method, and click "OK."
Note
When the above window appears, all communication functions presently performed is turned OFF.
All other monitors performed in other windows are also stopped. Resume monitor after synchronization is completed.