130
How to use MEXE02
Waveform monitor
The motor rotation speed or the status of I/O signals can be checked in a waveform format.
Refer to the operating manual of the
MEXE02
for the procedures to operate the applicable products using the
MEXE02
.
z
CH1 to CH4 (analog CH)
The rotation speed or the detected torque (actual torque), etc. can be checked. Using the waveform monitor can check
successive changes.
Monitored items Unit Range selection
Command speed (motor shaft) r/min 100, 200, 500, 1000, 2000, 5000
Actual speed (motor shaft) r/min 100, 200, 500, 1000, 2000, 5000
Inverter voltage V 1, 2, 5, 10, 20, 50
Actual torque % 10, 20, 50, 100, 200
Selection number − 1, 2, 5, 10
z
CH5 to CH12 (digital CH)
The ON/OFF status of signals can be checked. There is no setting for range and oset in the digital CH.
Monitored items Monitored items Monitored items Monitored items Monitored items
ALM-A INFO-CLR INFO-TRQ-DE R-IN10 R-OUT11
ALM-B INFO-DRV INFO-UVOLT R-IN11 R-OUT12
ALM-RST INFO-DRVTMP M0 R-IN12 R-OUT13
D-IN0 INFO-DSLMTD M1 R-IN13 R-OUT14
D-IN1 INFO-IOTEST M2 R-IN14 R-OUT15
D-IN2 INFO-LOAD MOVE R-IN15 R0
D-IN3 INFO-NET-E MPS R-OUT0 R1
D-IN4 INFO-ODO R-IN0 R-OUT1 R2
DIR INFO-OVOLT R-IN1 R-OUT2 R3
D-OUT0 INFO-REV R-IN2 R-OUT3 REV (RUN/BRAKE)
D-OUT1 INFO-PCOUNT R-IN3 R-OUT4 SPEED-OUT
EXT-ERROR INFO-PTIME R-IN4 R-OUT5 STOP-MODE (FWD/REV)
FWD (START/STOP) INFO-RBT R-IN5 R-OUT6 SYS-BSY
HMI INFO-SET-E R-IN6 R-OUT7 TL
INFO INFO-SPD R-IN7 R-OUT8 TLC
INFO-CFG INFO-SPD-DE R-IN8 R-OUT9 VA
INFO-TRIP R-IN9 R-OUT10
z
Time scale
The following time scales can be set.
5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000