144
Information
17.3 Information codes
The information codes represents the generation status of information in a 8-digit hexadecimal number (it is possible to
read in 32-bit via RS-485 communication). If multiple information items are generated, they are represented in the OR
value of the information code.
Example) When information items of the overvoltage and the driver temperature are generated
Information code of overvoltage: 0000 0010h
Information code of driver temperature: 0000 0004h
OR value of two information codes: 0000 0014h
Information
code
Display in 32 bits
Information item
bit 31
to
bit 28
bit 27
to
bit 24
bit 23
to
bit 20
bit 19
to
bit 16
bit 15
to
bit 12
bit 11
to
bit 8
bit 7
to
bit 4
bit 3
to
bit 1
00000004h 0000 0000 0000 0000 0000 0000 0000 0100 Driver temperature
00000010h 0000 0000 0000 0000 0000 0000 0001 0000 Overvoltage
00000020h 0000 0000 0000 0000 0000 0000 0010 0000 Undervoltage
00000080h 0000 0000 0000 0000 0000 0000 1000 0000 Load
00000100h 0000 0000 0000 0000 0000 0001 0000 0000 Speed
00000200h 0000 0000 0000 0000 0000 0010 0000 0000 Operation data setting error
00001000h 0000 0000 0000 0000 0001 0000 0000 0000 Operation prohibited
00008000h 0000 0000 0000 0000 1000 0000 0000 0000 RS-485 communication error
00080000h 0000 0000 0000 1000 0000 0000 0000 0000 Rotation amount meter
00100000h 0000 0000 0001 0000 0000 0000 0000 0000 Tripmeter
00200000h 0000 0000 0010 0000 0000 0000 0000 0000 Odometer
01000000h 0000 0001 0000 0000 0000 0000 0000 0000 Torque limiting value setting error
02000000h 0000 0010 0000 0000 0000 0000 0000 0000 Rotation speed setting error
04000000h 0000 0100 0000 0000 0000 0000 0000 0000 Main power supply time
08000000h 0000 1000 0000 0000 0000 0000 0000 0000 Main power supply count
10000000h 0001 0000 0000 0000 0000 0000 0000 0000 Operation start limit mode
20000000h 0010 0000 0000 0000 0000 0000 0000 0000 I/O test mode
40000000h 0100 0000 0000 0000 0000 0000 0000 0000 Conguration request
80000000h 1000 0000 0000 0000 0000 0000 0000 0000 Power cycling request