142
Information
17.2 Information lists
bit Information
Information bit
output signal
Cause Condition to reset and clear
2 Driver temperature INFO-DRVTMP
The internal temperature of the driver
increased to the value set in the "Driver
temperature information" parameter or
higher.
The internal temperature of the driver
fell below the value set in the "Driver
temperature information" parameter by 5°C.
4 Overvoltage INFO-OVOLT
The internal voltage of the driver increased
to the value set in the "Overvoltage
information" parameter or higher.
The internal voltage of the driver fell
below the value set in the "Overvoltage
information" parameter by 0.5 V.
5 Undervoltage INFO-UVOLT
The internal voltage of the driver dropped
to the value set in the "Undervoltage
information" parameter or lower.
The internal voltage of the driver exceeded
the value set in the "Undervoltage
information" parameter by 0.5 V.
7 Load INFO-LOAD
The detected torque of the motor increased
to the value set in the "Load information"
parameter or larger.
The detected torque of the motor fell below
the value set in the "Load information"
parameter.
8 Speed INFO-SPD
The detected speed of the motor increased
to the value set in the "Speed information"
parameter or higher.
The detected speed of the motor fell below
the value set in the "Speed information"
parameter by 5 r/min.
9
Operation data setting
error
INFO-SET-E
There is an error in the combination of
parameters set in the operation data.
Setting method
⇒
p.19
The data was set again so that the
combination of parameters set in the
operation data was correct.
12 Operation prohibited INFO-DRV
Any of the following operations was
performed and caused a state of operation
prohibition.
*1
•
The operation input signal is being
ON when "I/O test" or "teaching/
remote operation" of the
MEXE02
was
completed.
*2
•
Conguration was executed in a state
where the motor would immediately
rotate by changing the assignment or the
logic level setting of input terminals.
•
An operation of the operation data
number, which setting method of
operation data was a state of abnormal
combination, was executed.
Any of the following operations was
performed, and the state of operation
prohibition was released.
•
The operation input signal was turned
OFF.
*2
•
The operation data setting method was
set again.
•
The operation data number was changed
to an operation data number that the
setting is correct.
15
RS-485 communication
error
INFO-NET-E
The number of consecutive RS-485
communication errors reached the value
set in the "RS-485 communication error
information" parameter.
RS-485 communication was performed
properly.
19
Rotation amount
meter
*3
INFO-REV
The rotation amount inside the driver was
out of the range of the "Rotation amount
meter information" parameter.
Any of the following operations was
performed, and the rotation amount was
brought within the setting range of the
"Rotation amount meter information"
parameter.
•
The "Rotation amount meter information"
parameter was set again.
•
"Clear rotation amount meter" was
executed with the
MEXE02
.
•
"Clear rotation amount meter" was
executed via RS-485 communication.
*1
The motor does not move if the driver is in a state of operation prohibition.
*2
A condition to turn the operation input signal ON varies depending on the setting of the "Operation input mode selection"
parameter.
*3
The rotation amount is reset when the power supply is turned o because it is saved in the RAM. It can also be reset with the
MEXE02 or the maintenance command via RS-485 communication.
If a value in the "Rotation amount meter information" parameter is set so that the negative side is larger than the positive side or the
positive side is smaller than the negative side, the information will be a state of always being generated.