58
I/O signals
10.3 Signals list
Input signals
Assignment
number
Signal name Description
0 Not used Set when the input terminal is not used.
8 ALM-RST This is a signal to reset the alarm being generated. (The signal is reset at the ON edge of the input.)
14 INFO-CLR This is a signal to clear the information being generated. (The signal is reset at the ON edge of the input.)
16 HMI
*1
This is a signal to switch whether to enable or disable the function limitation of the
MEXE02
.
(The function limitation is released when this signal is turned ON.)
22 TL
*1
This is a signal to switch whether to enable or disable the torque limiting function.
(The torque limiting function is enabled when this signal is turned ON.)
25 EXT-ERROR
*2
This is a signal to generate the external stop alarm and stop the motor forcibly.
(The alarm is generated when this signal is turned OFF.)
58 FWD (START/STOP)
*3
This is a signal to rotate or stop the motor. (The motor rotates when this signal is turned ON.)
The function and name vary depending on the setting of the "Operation input mode selection"
parameter.
59 REV (RUN/BRAKE)
*3
64 M0
These are signals to select the operation data number.65 M1
66 M2
72 STOP-MODE (FWD/REV)
*3
This is a signal to set the motor movement.
The function and name will change by the setting of the "Operation input mode selection" parameter.
STOP-MODE: This is a signal to select how to stop the motor.
(OFF: Deceleration stop, ON: Instantaneous stop)
FWD/REV: This is a signal to select the motor rotation direction.
(OFF: Reverse direction, ON: Forward direction)
80 R0
These are general signals.
81 R1
82 R2
83 R3
*1
A state of an internal signal is always ON (active state) if it is not assigned to the direct input and remote input.
*2
The EXT-ERROR input is not available to the assignment of the remote input. A state of an internal signal is always ON (active state) if
the EXT-ERROR input is not assigned.
*3
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be applied.
Output signals
Assignment
number
Signal name Description
0 Not used Set when the output terminal is not used.
8 ALM-RST_R
These are signals to output a response to an input signal.
14 INFO-CLR_R
16 HMI_R
22 TL_R
25 EXT-ERROR_R
58 FWD (START/STOP)_R
*1
59 REV (RUN/BRAKE)_R
*1
64 M0_R
65 M1_R
66 M2_R
72 STOP-MODE (FWD/REV)_R
*1
80 R0_R
81 R1_R
82 R2_R
83 R3_R
*1
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be applied.