If you are new to this product, read this chapter to understand the operating methods along with the operation ow.
This is an example how to set operation data and parameters to the driver and operate the motor using a host controller.
Note
•
Before operating the motor, check the surrounding conditions to ensure safety.
•
After changing a parameter, it may be required to perform Conguration or turn on the driver power again in order
to update the new setting.
Refer to p.97 for details about the update timing.
STEP1 Checking the installation and connection
➡
STEP2 Setting switches
➡
This operation is performed under the following
conditions.
•
Number of drivers connected: 1 unit
•
Address number: 1 (set by the switch)
•
Transmission rate: 115,200 bps
•
Termination resistor: Set to be enable
STEP3 Setting the communication parameters
➡
STEP4 Turning on the power supply again
➡
STEP5 Operating the motor
➡
STEP6 Checking the operation
STEP1 Checking the installation and connection
Connection diagram
CN1 CN2
+
-
CN3
CN6
CN5
C-DAT
C-ERR
CN4
PWR/ALM
IDTERM.
NO
24 VDC
Motor
MEXE02
DC power supply
Connected to
the CN1
Connected to the CN5 or CN6
RS-485 communication cable
Connected to
the CN3
Connected to
the CN4
CN5/CN6 pin assignment
Pin No. Signal name Description
1 TR+ RS-485 communication signal (+)
2 TR− RS-485 communication signal (
-
)
3 GND GND