Parameter
9.8 Communication and I/F function
A: Update immediately, C: Update after executing Conguration, D: Update after turning on the power again
Parameter name Description Setting range
Factory
setting
Update
USB-ID enable
Sets whether to enable or disable the
USB-ID (serial number). When it is set to
"Disable," the USB-ID is automatically set
to a random number.
0: Disable
1: Enable
1
D
USB-ID
Sets the USB-ID (serial number).
The COM port at power-on can be xed.
0 to 999,999,999 0
USB-PID
Sets the product ID to be displayed in the
COM port.
0 to 31 0
RS-485 Receive packet
monitor
Selects the monitoring target in the
RS-485 communication.
0: All
1: Only own address
0 A
Communication ID Sets the address number (slave address).
−1: The switch setting of the driver is followed
1 to 15: Slave address 1 to 15
※
Do not use 0.
−1
D
Baudrate Sets the transmission rate.
0: 9,600 bps
1: 19,200 bps
2: 38,400 bps
3: 57,600 bps
4: 115,200 bps
5: 230,400 bps
4
Communication order
Sets the byte order of 32-bit data.
Set when the arrangement of
communication data is dierent from the
master.
0: Even Address-High Word & Big-Endian
1: Even Address-Low Word & Big-Endian
2: Even Address-High Word & Little-Endian
3: Even Address-Low Word & Little-Endian
0
Communication parity Sets the communication parity.
0: None
1: Even parity
2: Odd parity
1
Communication stop bit Sets the communication stop bit.
0: 1 bit
1: 2 bits
0
RS-485 communication
timeout alarm
Sets the condition in which the RS-485
communication timeout alarm is
generated.
0: Not monitored
1 to 10000 ms
0
A
RS-485 communication
error alarm
A communication error alarm
is generated when the RS-485
communication error has occurred by
the number of times set here.
0: Disable
1 to 10 times
3
Transmission waiting
time
Sets the transmission waiting time. 0.0 to 1000.0 ms 3.0
D
Silent interval Sets the silent interval.
0.0: Set automatically
0.1 to 10.0 ms
0.0
Slave error response
mode
Sets the response when the slave error
occurred.
0: Normal response is returned
1: Exception response is returned
1 A
Initial group ID
Sets the address of a group (address
number of parent slave). It is stored even
if the power is turned o.
−1: Disable (no group transmission)
1 to 15: Group ID
※
Do not use 0.
−1 C