56
I/O signals
10.2 Remote I/O
Remote I/O is I/O to be accessed via RS-485 communication.
Assignment to input signals
The following signals are assigned at the time of shipment. Input signals assigned to the remote inputs R-IN0 to R-IN15
can be changed using parameters. Refer to p.58 for the input signals list that can be assigned.
Remote I/O signal name Factory setting Remote I/O signal name Factory setting
R-IN0 M0 R-IN8 Not used
R-IN1 M1 R-IN9 Not used
R-IN2 M2 R-IN10 Not used
R-IN3 FWD (START/STOP)
*
R-IN11 Not used
R-IN4 REV (RUN/BRAKE)
*
R-IN12 Not used
R-IN5 STOP-MODE (FWD/REV)
*
R-IN13 Not used
R-IN6 Not used R-IN14 Not used
R-IN7 ALM-RST R-IN15 Not used
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be
applied.
Related parameters
Parameter name Description Factory setting
R-IN0 input function selection
Selects the input signal to assign to the remote input (R-IN0 to
R-IN15).
64: M0
R-IN1 input function selection 65: M1
R-IN2 input function selection 66: M2
R-IN3 input function selection 58: FWD (START/STOP)
*
R-IN4 input function selection 59: REV (RUN/BRAKE)
*
R-IN5 input function selection 72: STOP-MODE (FWD/REV)
*
R-IN6 input function selection 0: Not used
R-IN7 input function selection 8: ALM-RST
R-IN8 input function selection 0: Not used
R-IN9 input function selection 0: Not used
R-IN10 input function selection 0: Not used
R-IN11 input function selection 0: Not used
R-IN12 input function selection 0: Not used
R-IN13 input function selection 0: Not used
R-IN14 input function selection 0: Not used
R-IN15 input function selection 0: Not used
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be
applied.
Note
When the same input signal is assigned to multiple input terminals, the function will be executed if any one of the
terminals is turned ON. (Except for HMI input and TL input)
For the HMI input and the TL input, they are always being ON if not assigned.
If these signals are assigned to both direct I/O and remote I/O or to multiple terminals, the function will be enabled
when all terminals are turned ON.