57
I/O signals
Assignment of output signals
The following signals are assigned at the time of shipment. Output signals assigned to the remote outputs R-OUT0 to
R-OUT15 can be changed using parameters. Refer to p.58 for the output signals list that can be assigned.
Remote I/O signal name Factory setting Remote I/O signal name Factory setting
R-OUT0 M0_R R-OUT8 SYS-BSY
R-OUT1 M1_R R-OUT9 DIR
R-OUT2 M2_R R-OUT10 MPS
R-OUT3 FWD (START/STOP)_R
*
R-OUT11 Not used
R-OUT4 REV (RUN/BRAKE)_R
*
R-OUT12 Not used
R-OUT5 STOP-MODE (FWD/REV)_R
*
R-OUT13 MOVE
R-OUT6 INFO R-OUT14 VA
R-OUT7 ALM-A R-OUT15 TLC
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be
applied.
Related parameters
Parameter name Description Factory setting
R-OUT0 output function selection
Selects the output signal to assign to the remote outnput
(R-OUT0 to R-OUT15).
64: M0_R
R-OUT1 output function selection 65: M1_R
R-OUT2 output function selection 66: M2_R
R-OUT3 output function selection 58: FWD (START/STOP)_R
*
R-OUT4 output function selection 59: REV (RUN/BRAKE)_R
*
R-OUT5 output function selection 72: STOP-MODE (FWD/REV)_R
*
R-OUT6 output function selection 135: INFO
R-OUT7 output function selection 129: ALM-A
R-OUT8 output function selection 136: SYS-BSY
R-OUT9 output function selection 148: DIR
R-OUT10 output function selection 168: MPS
R-OUT11 output function selection 0: Not used
R-OUT12 output function selection 0: Not used
R-OUT13 output function selection 134: MOVE
R-OUT14 output function selection 141: VA
R-OUT15 output function selection 140: TLC
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be
applied.